Materials whose thickness changes under pressure can also be measured! Thermal conductivity measurement device.

Automatic measurement just by setting the sample! A thermal conductivity measurement device ideal for measuring electrode materials and insulating materials.

The "IE-1230" is a thermal conductivity measurement device that measures the thermal conductivity of materials such as metals using the "temperature gradient method (plate comparison method)." It allows for easy measurement of thermal conductivity, as it automatically measures the temperature distribution and the thickness of the sample simply by setting it up, making it more convenient than conventional products. It is capable of measuring the thickness during thermal conductivity measurement under pressure, allowing for the measurement of materials whose thickness changes under pressure. 【Features】 ■ Easy thermal conductivity measurement while applying pressure ■ Thickness can be measured under pressure using a thickness sensor ■ Automatically measures thermal conductivity after setting the sample ■ Capable of measuring thickness as thin as 0.05mm *For more details, please download the catalog or contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Thermal conductivity measurement device

This is a device for measuring the thermal conductivity of plastic materials as they change from a molten state to a solid state through natural heat dissipation.

- Automatic measurement of up to 50 temperature levels is possible by setting the sample. - The heat capacity of the probe is minimized to improve measurement accuracy. - Continuous operation is possible by following the thermal contraction of the sample with a piston heater. - By creating a vacuum inside the cylinder before sample insertion, concerns about bubble contamination in the sample are alleviated. - The piston pressurization cylinder can be used as a cleaning cylinder, making cleaning easy. - Over-temperature prevention features for the piston heater and cylinder heater. - Compact and lightweight.

  • Other measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

LFA 467 HyperFlash / Thermal Conductivity Measurement Device

Light Flash Analyzer for Thermal Diffusivity (Thermal Conductivity) Measurement Device.

The latest tabletop Xe flash analyzer enables rapid, easy, and highly accurate measurement of thermal diffusivity and thermal conductivity. It covers a wide measurement temperature range from -100°C to 1250°C, and with improved pulse width, it can also handle high thermal conductivity samples of thin films that were difficult to measure conventionally. It comes standard with a maximum of 16 auto-sample changers, allowing for highly accurate measurements of samples ranging from large diameters to very small diameters.

  • Other analytical equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

HFM 446 Lambda / Thermal Conductivity Measurement Device for Insulation Materials

Devices that enable energy conservation and efficient use.

The HFM 446 Lambda is a thermal conductivity measurement device suitable for measuring the thermal conductivity of materials with low conductivity, such as insulation materials. The sample is placed between a hot plate and a cold plate, and the temperature difference is adjusted while the heat flux is measured with sensors. Stability is achieved in about 15 minutes, allowing for more measurements and increased productivity. With two heat flux sensors positioned, the error remains below 0.5% within 15 minutes, and during tests lasting several days, a very stable conductivity of 0.10 to 0.25% can be obtained. This allows for reliable data collection for simple inspections of product variability during the manufacturing process. 【Features】 ■ High precision, stability, and accuracy ■ Fast and easy operation ■ Automatic operation ■ Short setup time and quick start *For more details, please refer to the catalog or feel free to contact us.

  • Other analytical equipment